three wavelength laser hair elimination device
Shop the 2in1 Soprano Titanium Ice Platinum Diode Laser. This ND:YAG device characteristics 3 wavelengths (755, 808, 1064nm) for painless hair elimination.2-in-one Soprano Titanium Ice 4000W Triple Wavelength Diode & ND:YAG Laser Equipment
Attain Specialist-grade benefits With all the Soprano Titanium Ice Platinum, a powerful 2-in-1 procedure combining 3-wavelength diode laser technological innovation for painless hair elimination as well as a Q-Switched ND:YAG laser for tattoo elimination and pores and skin rejuvenation. Geared up by using a 4000W high-electricity motor and 5-degree adjustable cooling technological innovation, this CE-Accredited device supplies Safe and sound, economical, and long-lasting success for all skin types and system regions.
Hair Removal: Triple wavelength (755nm, 808nm, 1064nm) for all skin tones
Skin Correction: Q-Switched ND:YAG for tattoo elimination and carbon peeling
Comfort: 5-Stage adjustable cooling method for a painless experience
Electricity: 4000W superior-Power density with German Diode Arrays
Crucial Characteristics
3-Wavelength Diode Technologies: Integrates 755nm (Alexandrite), 808nm (Velocity), and 1064nm (YAG) wavelengths into one applicator to target various hair depths and buildings concurrently.
Twin-Perform System: A true two-in-1 workstation that includes a focused Diode laser for long lasting hair reduction along with a Q-Switched ND:YAG laser for pigmented lesion cure and tattoo removing.
State-of-the-art five-Stage Cooling: Features the “Titanium Ice” five-level adjustable cooling technological innovation that retains the sapphire tip at an optimal temperature, ensuring the procedure stays comfy and pain-free.
Large Output Functionality: Driven by a huge 4000W electric power provide and German-imported Diode arrays, offering around 2000mj energy density for quickly and powerful clinical outcomes.
Massive Touchscreen Interface: Outfitted which has a high-definition interactive Show for precise Management around Power amounts, pulse frequency, and cooling intensity throughout unique cure modes.
Compatibility & Ideal Use
Total Physique Software: Secure and effective for use around the face (upper lip, chin), underarms, bikini line, arms, legs, back again, Mainland China and upper body.
All Skin Sorts: The triple wavelength system is intended to do the job properly on all skin tones (Fitzpatrick scales I-VI) and hair colors, which includes fine and light-weight hair.
Pores and skin Rejuvenation: Utilize the ND:YAG tackle with the black doll (carbon) suggestion for deep pore cleansing, pores and skin whitening, and anti-growing older solutions.
Tattoo & Pigment Elimination: Focus check here on darkish and colored inks precisely using the Q-Switch frequency for non-invasive elimination of tattoos and freckles.
Set up Suggestions
Drinking water Cooling Setup: This significant-electric power laser click here involves distilled drinking water for its cooling program; make sure the h2o tank is stuffed into the encouraged degree before powering on the equipment for The 1st time.
Tackle Link: Carefully align the pins from the laser handles While using the machine ports and safe the locking mechanism to be certain secure sign and cooling fluid transmission.
Voltage Verification: The equipment supports 110V and 220V; ensure your electricity outlet matches the particular voltage options with the device to avoid electrical hurt.
Parameter Calibration: For brand new customers, it is usually recommended to start out treatment options at the bottom Electricity configurations and step by step boost based on the client’s skin sensitivity and opinions.
Product Specs
Brand name Title emszero
Model Amount Titanium 2-in-one (4000W)
Laser Wavelengths 755nm, 808nm, 1064nm (Diode) / 532nm, 1064nm, 1320nm (ND:YAG)
Energy Output 4000W
Vitality Density Around 2000mj (Adjustable)
Cooling Level five Amounts Adjustable Sapphire Cooling
Certification CE
Voltage Compatibility AC 110V/220V, fifty/60Hz
Packing Checklist
one x Soprano Titanium 2-in-1 Main Console (4000W)
1 x three-Wavelength Diode Laser Take care of
1 x Q-Switch ND:YAG Laser Tackle
3 x Specialized ND:YAG Strategies (532nm, 1064nm, 1320nm)
1 x Electricity Cable & Foot Pedal
one x Person Handbook & Protecting Goggles Established
Warnings & Protection Notes
Eye Safety: Often use the furnished laser-basic safety goggles all through Procedure to circumvent long-lasting eye destruction from stray laser reflections.
Never Operate Dry: Tend not to operate the device without having filling it with distilled water; check here managing the laser and not using a operating cooling loop will bring more info about immediate inner hardware failure.
Contraindications: Never use this device on locations with open wounds, active bacterial infections, or on people who are Expecting or have light-weight-sensitive medical problems.
Cooling Servicing: Change the distilled h2o every three months to be sure the internal pump and laser arrays keep on being free of mineral buildup and overheating.